Thermocouples and compensating lead wires

Product Range

Heating Conductors and Resistance Alloys in thermocouple wire

Our website with extensive technical information is currently under construction and this page is not yet or not completely available. If you require information on thermocouples and compensating lead wires in advance, we will be happy to provide you with information on this product. Please use the contact form, send us an e-mail or call us on +49 (0) 6074 855-0.

Delivery program (excerpt)

Alloy
Analysis
Standards
Spec. resistance in Ohm mm2/m
Density in g/cm3
Recommended max. temperature in °C
Approximate melting point
NiCuCrFeotherDINW.St.
Thermo KP(X)90100––IEC 548-0.6828.7212601425
Thermo KN(X)95–0–5(MnS iAlCo)IEC 548-0.2748.6112601400
Thermo JP(X)––0100–IEC 548-0.1007.867601535
Thermo JN(X)45550––IEC 548-0.4998.897601280
Thermo NP(X)Rest–14,2–1,4Si/ 0,1MgIEC 548-0.9648.5012601410
Thermo NN(X)Rest–––4,4Si/ 0,1MgIEC 548-0.3668.6912601340

Please speak to us if you require an alloy that is not listed here.